Cyber Monday 2024! Hurry Up, Grab the Special Discount - Save 25% - Ends In 00:00:00 Coupon code: SAVE25
Welcome to Pass4Success

- Free Preparation Discussions

Fortinet Exam NSE7_LED-7.0 Topic 1 Question 5 Discussion

Actual exam question for Fortinet's NSE7_LED-7.0 exam
Question #: 5
Topic #: 1
[All NSE7_LED-7.0 Questions]

Refer to the exhibit.

Examine the FortiGate configuration FortiAnalyzer logs and FortiGate widget shown in the exhibit

An administrator is testing the Security Fabric quarantine automation The administrator added FortiAnalyzer to the Security Fabric and configured an automation stitch to automatically quarantine compromised devices The test device (::.:.:.!) s connected to a managed Fort Switch dev :e

After trying to access a malicious website from the test device, the administrator verifies that FortiAnalyzer has a log (or the test connection However the device is not getting quarantined by FortiGate as shown in the quarantine widget

Which two scenarios are likely to cause this issue? (Choose two)

Show Suggested Answer Hide Answer
Suggested Answer: B, D

According to the exhibits, the administrator has configured an automation stitch to automatically quarantine compromised devices based on FortiAnalyzer's threat detection services. However, according to the FortiAnalyzer logs, the test device is not detected as compromised by FortiAnalyzer, even though it tried to access a malicious website. Therefore, option B is true because FortiAnalyzer does not have a valid threat detection services license, which is required to enable the threat detection services feature. Option D is also true because FortiAnalyzer does not consider the malicious website an indicator of compromise (IOC), which is a criterion for identifying compromised devices. Option A is false because the web filtering rating service is working, as shown by the log entry that indicates that the test device accessed a URL with a category of ''Malicious Websites''. Option C is false because the device does not need to have FortiClient installed to be quarantined by FortiGate, as long as it is connected to a managed FortiSwitch device.


Contribute your Thoughts:

Currently there are no comments in this discussion, be the first to comment!


Save Cancel
az-700  pass4success  az-104  200-301  200-201  cissp  350-401  350-201  350-501  350-601  350-801  350-901  az-720  az-305  pl-300  

Warning: Cannot modify header information - headers already sent by (output started at /pass.php:70) in /pass.php on line 77